Parent Command
>> CONVERGE
Subcommand
-
Description
In TOUGH2, time step size can be controlled in various ways
(see Pruess [1987] for a description of input variables DELTEN, DLT,
DELTMX, NOITE, REDLT, and MOP(16)).
The time step is also automatically adjusted in order for the simulation
time to land on any of the specified calibration or printout times.
This may lead to very small time steps or even convergence failures
(see command
Example
> COMPUTATION
>> CONVERGE
>>> DELTFACT: 1.0 (as in standard TOUGH2)
>>> allow : 20 CONSECUTIVE time steps converging in 1 iteration
<<<
<<
See Also