Parent Command
> OBSERVATION
Subcommand
>>> CONNECTION
Description
This command selects as an observation type the flow rate of phase iphase or
total fluid flow rate or heat flux. This observation type refers to a connection.
The phase name phase_name or phase number iphase, which depend on the EOS
module being used, are listed in the iTOUGH2 header. They can be specified
either on the command line or using the subcommand
Example
> OBSERVATION
>> GAS FLOW rate
>>> CONNECTION: INJ_1 ELM_2
>>>> ANNOTATION : Gas flow
>>>> FACTOR : -16.666667 to convert from m^3/min to kg/s
>>>> DATA on FILE : inject.dat
>>>> RELATIVE error: 3.0 %
<<<<
<<<
>> FLOW rate
>>> CONNECTION: A11_1 A11_2 B11_1 B11_2 C11_1 C11_2 &
D11_1 D11_2 E11_1 E11_2 F11_1 F11_2
>>>> ANNOTATION: Flow across boundary
>>>> LIQUID PHASE flow rate
>>>> take the SUM
>>>> of the ABSOLUTE values of the 6 flow rates
>>>> DATA in [kg/s], time in [MINUTES] are on FILE: outflow.dat
>>>> standard DEVIATION: 0.1 kg/sec
<<<<
<<<
<<